This parameter of the command line tool allows you to define the number of rows/columns around the edges that you wish to “clean” (remove the EMI noise) if a certain amount of touches happens. (Usually, if you have false touches around the edges).
Syntax:
displaxservice -a 127.0.0.1 --te2fnref o x y
How to select one, two, three or more lines around the edges (the value used in ‘o’):
Each column and row as a value of ’50’.
If you want to select:
Values used in ‘x’:
From one to the maximum of touches your SKIN support. We do recommend to keep this number between 2 and 3.
Values used in ‘y’:
From 0 to the maximum touches your SKIN support.
We do recommend to use 0, as in that case this command only will be triggered when no one is touching the SKIN (on the active area).
Example:
displaxservice --te2fnref 100 2 0
The -te2fnref will be triggered if :
If you want to make this changes permanent (save them to the controller) you should run the following command:
displaxservice --device-settings save