Reset button operation

Reset button operation

The Reset button has various functions.

The different functions are triggered depending on the amount of time the button is pressed for.

The button, accessible through a small hole at the bottom of the tag,  should be pressed using a small pin, screwdriver, or toothpick.


Every 2 seconds after pressing the button, the tag light blinks according to a targeted function id. 

To execute a function, the user must release the button within a time window of 2 seconds after the light effect is presented. 


Please refer to the table below for all function references:


Function ID

Description

Selection process

Tag operation when selected

0

Exit Transport mode

Click

Nothing (turns on normally)

1

Enter Transport mode

2s < Press button < 4s

Tag blinks/vibrates 1 time after 2s

2

Calibration

4s < Press button < 6s

Tag blinks/vibrates 2 times after 4s

3

Factory reset

Press button > 6s

Tag blinks/vibrates 3 times after 6s










    • Related Articles

    • TUIO Simulator

      The TUIO Simulator is an excellent tool to demonstrate Object Recognition advantages. Go to the TUIO Simulator download page here. For further details on the global operation and message structure, see https://www.tuio.org/ and ...
    • Touches over TUIO

      To configure a DISPLAX Skin to send Touch events through TUIO protocol, click on the TUIO icon (upper right corner in DISPLAX Connect), select the connected Touch Controller, enter the IP and Port information, and click on the “ADD TUIO CLIENT” ...
    • Tag effects

      A DISPLAX Active OR tag offers two features of feedback: light and vibration. There are two ways these features can be used: programmaticaly (see DisplaxSDK), on Displax Connect (mainly for testing purposes, see here), The sleep mode timeout is reset ...