Object Recognition on Multiple Tiles

Object Recognition on Multiple Tiles

Object Recognition on Multiple DISPLAX Tile Units

DISPLAX Tile supports Object Recognition (OR) across multiple Tile units installed side by side, whether they are connected via Daisy Chain or direct connections.

Each Tile unit operates independently for Object Recognition and must be configured individually in DISPLAX Connect.


Overview

When using multiple DISPLAX Tile units together, Object Recognition can be enabled on all of them simultaneously.
To achieve this, each Tile must send its Object Recognition data through a dedicated TUIO client using a unique network port.

This ensures that object and touch data from each Tile is correctly routed to the application.


Configuration Requirements

To enable Object Recognition on multiple Tile units:

  1. Open DISPLAX Connect

  2. For each connected Tile controller:

    • Enable TUIO output

    • Configure a separate TUIO client

    • Assign a unique port number (for example: 3333, 3334, 3335, etc.)

  3. Repeat the process for every Tile unit in the setup

Each Tile must have:

  • Its own TUIO client

  • A different port from the others



Important Notes and Limitations

Tag Placement Across Tiles

Even though DISPLAX Tile features an ultra-thin bezel, it is not possible to correctly recognize a TAG placed across two adjacent Tile units.

  • TAGs must be placed entirely within the active area of a single Tile

  • Objects overlapping two Tiles will not be detected correctly


TAG Limits per Tile

  • You can use up to 6 Passive TAGs per Tile unit

  • TAG detection and tracking are handled locally by each Tile


TUIO Touch Limitations

  • TUIO is limited to 20 simultaneous touches per client

  • When using multiple Tiles:

    • Each Tile (TUIO client) has its own 20-touch limit

    • Touch limits are not shared across Tiles


Best Practices

  • Use a clear port mapping strategy for each Tile (e.g., sequential ports)

  • Test Object Recognition:

    • On each Tile individually

    • Then with all Tiles active together

  • Avoid placing objects, hands, or TAGs across Tile borders

  • Ensure stable USB connections and proper grounding for all Tile units


Video Tutorial

The video below demonstrates how to:

  • Add multiple TUIO clients

  • Assign different ports

  • Enable Object Recognition on multiple DISPLAX Tile units




For more information regarding Object Recognition, click here.


    • Related Articles

    • Frequently Asked Questions

      When using two or more DISPLAX Tile units, how many touch points are available? Each DISPLAX Tile unit supports up to 100 simultaneous touch points. When multiple Tile units are used together: Touch points are added per Tile The maximum total number ...
    • Calibrate 2 or More TILEs

      The process of calibrating 2 or more TILE units would be exactly the same, regardless of how many TILE units you are using. In the following example we demonstrate 3 TILE units working as a Videowall (3 Columns and 1 Row). First, select the TILE you ...
    • Set Up Mosaic using NVIDIA

      Creating a Video Wall Mosaic with DISPLAX Tile When using multiple DISPLAX Tile units together, you can merge them into a single large display (mosaic) using your graphics card control panel. This allows the operating system and applications to treat ...
    • RS232

      The TILE is equipped with the RS 232 communication protocol. This makes it possible for multiple TILEs to be daisy-chained via an RJ45 cable, allowing for controlling all linked TILEs' settings simultaneously. Using the TILE's remote control will ...
    • Video Wall Calibration

      DISPLAX Connect version 3.7.0 and later includes the feature, Video Wall Calibration - added to our existing calibration modes to ease the process of calibrating multiple TILEs in a videowall or table, at once. DISPLAX Connect will detect all TILES ...