The Sensor Scan feature automatically detects and applies the correct number of channels (rows and columns) for the connected DISPLAX Skin Zeeto sensor.
This ensures that the controller is correctly configured to match the sensor’s geometry, improving accuracy and eliminating manual setup errors.


What Is Sensor Scan?

Each DISPLAX sensor is built from a grid of conductive rows (TX-channels) and columns (RX-channels) that determine its touch area.
The Sensor Scan function automatically identifies this configuration, setting the correct frame size in DISPLAX Connect.

💡 This feature is available only for DISPLAX Zeeto controllers.


How to Use Sensor Scan

  1. Open DISPLAX Connect.

  2. Click on the Sensor Tools button in the main interface.

  3. Inside Sensor Tools, click Sensor Scan.


Step 1 – Verify Sensor Size

If the current sensor size is not set to the maximum supported configuration, a warning message will appear:


⚠️ To start a sensor scan, the sensor size must be set to the maximum supported value (32x32).

Click Continue to proceed or Cancel to adjust settings manually.


Step 2 – Scanning Process

The controller will now scan the sensor to detect its active rows and columns.
Avoid touching the sensor during this step to prevent interference.

Once completed, the following confirmation window will appear:


This shows the detected frame size (for example, 16x10).
Click Apply to save the detected configuration or Cancel to discard the result.


Step 3 – Applying Changes

After applying the detected frame size, a success message will confirm that the new configuration has been set:


Click Close to finish the process.


Benefits of Sensor Scan

  • Automatic configuration – Detects and sets rows and columns automatically.

  • Error prevention – Eliminates manual input mistakes.

  • Time-saving – Simplifies setup and reconfiguration.

  • Reliable performance – Ensures the controller matches the sensor geometry.


⚠️ Notes

  • The sensor must be connected to the controller before running a scan.

  • The Sensor Scan feature is supported only on DISPLAX Zeeto controllers.


    • Related Articles

    • Placing the Touch Sensor on the Glass

      How to place the Displax touch sensor on the glass After removing the protective liner, you must gently transfer the touch sensor from the wall to the glass substrate. This step requires care to avoid wrinkles, folds, or grid misalignment. Step 1 – ...
    • Placing the Touch Sensor on the Glass

      Lamination Laying the Touch Sensor over the Glass To remove the touch sensor from the wall, wet your fingers to prevent fingerprint marks on the film glue (Fig.16) Fig.16 To avoid folding or creasing the touch sensor, two people are required to ...
    • Connecting the Touch Controller to the Sensor

      Overview A proper connection between the touch sensor's FPC cables (flex) and the touch controller (PCB) is essential to ensure optimal touch performance. Each FPC cable has a specific connector port on the PCB. Ensure cables are fully seated and ...
    • Unpacking

      Unpack the Touch Sensor
    • Laminating with MIX and Squeegee

      Lamination Method Use this method to properly adhere the Displax touch sensor to the glass using the MIX solution and “squeegee 2.” Preparation Use “squeegee 2” only for lamination (do not reuse from cleaning) Confirm the touch sensor is already ...